当你使用 FISHView , 你可附加外挂式荧光滤镜转盘 ( Filter wheel ), 最多可装置 10 片荧光滤镜 ( Fluorescence Filters ).
滤镜转盘技术参数
F E A T U R E S : 
40 msec between adjacent filters. (10 position wheel)
31 msec between adjacent filters. (3 position wheel)
Serial and USB interfaces
Can control a variety of 25mm, 32mm and 50mm wheels
Controls one wheel and one optional shutter
Command set compatible with Lambda 10-C
Chopper drives
Universal power supply
订购须知 ( 基本配置 )
Sutter Automatic PC controlled Filter wheel for Fish (not including filters) with adapter
Standard set " A " 
DAPI/FITC/Texas Red filter set and multi-band cube, including 6 excitation filters 
Standard set " B "
DAPI/FITC/Orange filter set and multi-band cube, including 6 excitation filters
Advanced set  " C "
Quad Band Pass Filter cube without Exciter filters plus 5 Exciter filters for the following : 

1. Single Band UV exciter for DAPI/Hoechst/AMCA 

2. Single Band Violet exciter for attenuated DAPI 

3. Single Band Blue exciter for FITC 

4. Single Band Green exciter for Cy3, TRITC, Texas Red 

5. Single Band Red exciter for Cy5 
建议附加选配 荧光滤镜 ( Fluorescence Filter ) 订购须知 ( 基本配置 )
Triple Dual Band Orthogonal Set 

One for blue and red regions and 

One for green and NIR regions. 

Together they cover the entire spectrum from 450 - 800 nm.

DAPI Standard filter not including cube 
FITC Standard filter not including cube
CY5 Standard filter not including cube
CY3 Standard filter not including cube 
Aqua Standard filter not including cube 
TRITC Standard filter not including cube 
RGB Triple band pass Exciter Filter (Orange/Red including Rhodamine) not including cube 
配合其它探针或荧光标定染剂所需的其它滤镜,  请洽本公司专员

显微镜用滤镜 :

ASI SKY filter with cube ( 订购时, 请指明显微镜厂牌及机型 )

ASI DAPI filter with cube ( 订购时, 请指明显微镜厂牌及机型 )

VYSIS 荧光滤镜
Vysis Filter Set Configuration

PathVysion® HER-2 DNA Assay Filter Sets
The following filter sets are recommended for viewing and enumeration of the PathVysion® HER-2 Assay. These filter sets are optimized both for Vysis SpectrumGreenTM and SpectrumOrangeTM fluorophores and for paraffin-embedded specimen autofluorescence. The dual bandpass filter sets allow the user to view signals of each respective individual color fluorophore and the DAPI counterstain. The triple bandpass filter set allows the user to visualize the SpectrumGreen, SpectrumOrange, and DAPI fluorescent signals  simultaneously.

Vysis Filter Set Fluorophores Detected
DAPI/9- Orange (NB) dual bandpass SpectrumOrange and DAPI
DAPI/Green dual bandpass SpectrumGreen and DAPI
DAPI/Green/Orange (V.2) triple bandpass SpectrumGreen/SpectrumOrange/DAPI (specifically designed for viewing paraffin sections)

AneuVysion® Assay Filter Sets
The following filter set configuration provides the best microscope filter set-up for viewing and analysis of the AneuVysion Assay on uncultured amniocytes.

Vysis Filter Set Fluorophores Detected
Aqua single bandpass SpectrumAquaTM
Green single bandpass SpectrumGreenTM
Orange single bandpass SpectrumOrangeTM
DAPI/Green/Orange triple bandpass SpectrumGreen/SpectrumOrange/ DAPI

SpectraVysionTM Filter Sets
Microscope filter sets for the SpectraVysion System are designed for optimum analysis of the fluorophores used in the SpectraVysion Assay and for analysis using the SpectraVysion Imaging System.

Vysis Filter Set Fluorophores Detected
DAPI bandpass DAPI
Aqua single bandpass SpectrumAqua
Green single bandpass SpectrumGreen
Red single bandpass SpectrumRedTM
Gold single bandpass SpectrumGoldTM
FRed (far red) single bandpass SpectrumFRedTM

MultiVysion® Assay Filter Sets
The following filter set configuration provides the optimum filter set-up for viewing and imaging the MultiVysion Assay result.

Vysis Filter Set Fluorophores Detected
Aqua single bandpass SpectrumAqua
Blue single bandpass SpectrumBlueTM
Green single bandpass SpectrumGreen
Yellow single bandpass SpectrumGold
Red single bandpass SpectrumRed

If viewing only, without image analysis, the following filter sets are required:

Vysis Filter Set Fluorophores Detected
Aqua/Blue dual bandpass filter sets SpectrumAqua/SpectrumBlue
Red/Green dual bandpass filter sets SpectrumRed/SpectrumGreen
Yellow single bandpass SpectrumGold

UroVysionTM Assay Filter Sets

Vysis Filter Set Fluorophores Detected
DAPI single bandpass DAPI
Aqua single bandpass SpectrumAqua
Yellow single bandpass SpectrumGold
Red/Green dual bandpass SpectrumRed/SpectrumGreen

 

Filter Sliders/Holder

Vysis filter sets can be specified for most microscope types and models. Some of the most common filter holders and sliders and their dimensions are included in the following table.Vysis currently does not supply the new 8 position turret for the Olympus AX-70. These can be ordered directly from your microscope dealer and shipped to Vysis for filter mounting.

Microscope Model Filter Size Exciter Dichroic* Emitter
Leica Aristoplan 20 mm 9.2 mm max thickness 19 x 28 mm or 20 x 28 mm 20 mm 6.0 mm max thickness

Leica DM-RB (also called DM, DMR, LB)

21.9 mm 9.95 mm max thickness 22 x 29 mm or 21 x 29 mm  

Leica DMIRB (also called DMIR and LS) Note:Used in 8 position automated turret of DMR microscope

20 mm 22 x 27 mm 0.75 mm 20 mm
Leica Ploem or LaborLux 18 mm 7.5 mm max thickness 26 mm 0.80 mm max thickness 18 mm 5.0 mm max thickness
Nikon Standard 18 mm 7.5 mm max thickness 18 x 26 mm 4.1 mm 18 mm
Nikon Quadfluor (X2F-EFD3) 25 mm 24 x 34 mm cut corners 25 mm 3.5 mm max thickness
Olympus BH-2 (RFCA, DMB, DMG, BHA, B-LO918) 20mm 9.0 mm max thickness 19 x 28 mm or 18 x 26 mm 20 mm 2.4 mm max thickness or 19 mm 5.0 mm max thickness
Olympus B-Max, U-M510 or BX 25 mm 6.0 mm max thickness 38 x 26 mm 1.0 mm max thickness 25 mm 6.0 mm max thickness
Olympus IMT-2 20mm 5.0 mm max thickness 21 x 29 mm 20 mm 6.0 mm max thickness
Zeiss Axioline, AxioSkop, Axioplan, Axiophot, 1 FL, 2 FL, 3 FL, 4 FL, 5 FL, 6 FL Axioplan 2, Axiophot 2 (cubes turret-5 position) 25 mm 5.4 mm max thickness 25.5 x 36 mm 25 mm 5.0 mm max thickness
Zeiss Standard IM35, 2 FL, 46, 63, 01 18 mm 6.0 mm max thickness 22 mm 0.8 mm max thickness 18 mm 6.0 mm max thickness

*Dichroic filter thickness is indicated only when there is a maximum. The thickness should be less than 1.5 mm to minimize image shift.

 